8 master alarm, 9 alarm connections [relay (dry contact), 12 usb connections – KT&C KVR-1601S User Manual

Page 28: 13 grounding (earthing), 14 factory reset switch, 15 power supply connections

Advertising
background image

28

2.2.8 Master Alarm

(C, D, F, G, H, I and J Type)

 Alarm In sensor will be deactivated if Master Alarm is on.
 Connect Master Alarm In to ‘M’ connectors.

2.2.9 Alarm Connections [Relay (Dry Contact)]

(Except S Type)

 Connect Alarm Output (buzzer, siren, etc.) to ‘NO and/or NC’ connectors, Power to ‘COM’ connector and Ground to ‘GND’

connector.

2.2.10 RS-485/422 Connections

 PTZ Camera and Keyboard controller connector.
 Please use TX+, TX-, RX+ and RX- terminals accordingly.

2.2.11 RS-485 Over Coax Connection (S, A, B, C, I and J Type)

 PTZ Camera Connector
 Please connect Coax to ‘Video In’ and select any Protocol in Camera/PTZ setup.

NOTE

PTZ Camera must support RS-485 over Coax function in order to use this feature.

NOTE

When selecting Protocol, a user can choose any protocol from the Protocol list other than ‘NONE’. If ‘NONE’ is selected then

RS-485 over Coax will not work.

2.2.12 USB Connections

 There are up to four identical USB ports in front and in rear. It is possible to connect a USB memory stick to archive data or a

mouse to control the device.

2.2.13 Grounding (Earthing)

 Connection of ground wire is highly recommended to protect the DVR from external electric shock, such as lightening,

electrical surge.

2.2.14 Factory Reset Switch

 Reset the switch to restore all setup values to factory default. It also deletes System Log File.
 The switch is located in a pin hole of the back panel.
 Using a paper clip, press and hold the reset switch for 2-3 seconds and release until popup message will display.

2.2.15 Power Supply connections

S Type

:

Plug the power supply adapter (DC 12V, 3A, included) to ’DC12V’ connector and plug another side to power source.

Adapter input voltage is a free volt (100 VAC ~ 240 VAC). Please do not use any different power supply adapter because it

may cause the DVR to malfunction.

A, B and E (4CH) Type

: Plug the power supply adapter (DC 12V, 5A, included) to ’DC12V’ connector and plug another

side to power source. Adapter input voltage is a free volt (100 VAC ~ 240 VAC). Please do not use any different power supply

adapter because it may cause the DVR to malfunction.

C, D, E (8, 16CH), F, G (4CH) H, I and J Type

: Plug the power supply adapter (DC 12V, 6.67A, included) to ’DC12V

connector and plug another side to power source. Adapter input voltage is a free volt (100 VAC ~ 240 VAC). Please do not use

any different power supply adapter because it may cause the DVR to malfunction.

G (8 / 16CH) Type

: Plug the power source. Products input voltage is a free volt (100 VAC ~ 240 VAC).

 Please do not use any different power supply adapter because it may cause the DVR to malfunction.