4.3.5 Camera

 Please Click ( ) DEVICE>CAMERA and the following screen will display.

 Click ( ) the each Name box and the virtual keyboard will display. Then, register names of cameras.
 If a check box is checked on Use column, a video of the corresponding camera is recorded and displayed on the monitor.

However, if a user does not check the checkbox, “UNUSE” text will be displayed on the channel. If Click (

) ‘All’, all items are

check/uncheck at once.

 Click ( ) the each ID box and the virtual Numpad will display. Then, set ID Number of Cameras (i.e., 0 ~ 9999). The assigned

ID will be used for RS485/RS422/PTZ operations if applicable.

 If a check box is checked  on Covert box, a video is recorded but is not displayed on the monitor. If Click ( ) ‘All’, all items

are check/uncheck at once.

 Click ( ) each PTZ Column to set PTZ Settings connected to a corresponding camera. And the following screen will display.

 Click ( ) Drop-down list of Protocol / Baud Rate / Data Bit / Stop Bit / Parity to set PTZ settings of the Camera
 Menu, Tour and Pattern help users to use OSD function of PTZ camera.

- IF a PTZ camera itself supports OSD menu, use the setup values to enter and use the OSD menu using the DVR interface.
- If OSD entering command is 95 + PSET for example, designate 95 for Menu item,
- If shortcut key to use Tour function is 71 ~79 + PSET, designate 70 for Tour item and
- If shortcut key to use Pattern function is 81 ~ 89 + PSET, designate 80 for Pattern item.
- The setting information herein is used for PAN / TILT control in 5.1.5

(to be described).

- For further details on settings, please refer to the PTZ camera manual. Every PTZ camera manufacturer may have a

different setting on above. Please contact PTZ camera manufacturer for special preset reservation.

 If users Click ( )

, PTZ setting restores its default.

 Please choose ‘OK’ to confirm settings and choose ‘Cancel’ to cancel.
 Click ( ) Drop-down list of keyboard to select keyboard. This is used when a user uses Keyboard Joystick for DVR(s) and PTZ

Camera(s). You may disregard when you connect PTZ camera(s) to a Keyboard Joystick directly

NOTE

When using RS-485 over Coax for S, A, B, C, I (Analog) and J Type, users can select any protocol from the Protocol list other

than ‘NONE’. If ‘NONE’ is selected then RS-485 over Coax will not work. The PTZ camera should supports RS-485 over Coax

feature to work with.