3. INSTALLATION

3.

INSTALLATION

WARNING

Installation of the magnetic flowmeter must be
performed by expert engineer or skilled person-
nel. No operator shall be permitted to perform
procedures relating to installation.

3.1 Installation Location

IMPORTANT

Install the instrument in a location where it is not
exposed to direct sunlight. For ambient tempera-
ture, refer to Chapter 11 “OUTLINE”.
The instrument may be used in an ambient
humidity where the RH ranges from 0 to 100%.
However, avoid long-term continuous operation
at relative humidity above 95%.

3.2 Mounting

This instrument can be mounted on a 2-inch pipe in a
vertical or horizontal position depending on the
installation site.

Vertical Mounting

F0301.EPS

Mounting fixture

2-inch pipe

Nut

Washer

Screw

U-bolt

1. Fix the instrument on the mounting fixture using

four screws.

2. Fix the mounting fixture with the instrument

installed on a 2-inch pipe using a U-bolt.

Horizontal Mounting

F0302.EPS

2-inch pipe

Mounting fixture

Nut

Washer

Screw

U-bolt

1. Fix the instrument casing on the mounting fixture

using four screws.

2. Fix the mounting fixture with the instrument

installed on a 2-inch pipe using a U-bolt.

Figure 3.2.1

2-inch Pipe Mounting

Advertising