Yokogawa AXFA14G/C User Manual

Page 66

Advertising
background image

IM 01E20C02-01E

6-37

6. PARAMETER DESCRIPTION

(3) Display and output condition for setting alarm occurrences

50 Span > 10m/s

51 Span < 0.1m/s

52 TTL>10000p/s

53 TTL<0.0001p/s

54 4-20 Lmt Err

55 Multi Rng Err

56 H/L HH/LL Set

57 Dens Set Err

60 PLS >10000p/s

61 PLS > 5000p/s

62 PLS > 1000p/s

63 PLS > 500p/s

64 PLS > 25p/s

65 PLS > 15p/s

66 PLS > 10p/s

67 PLS > 5p/s

70 PLS<0.0001p/s

71 Meas Mod Set

72 Size Set Err

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Closed

(On)

Fixed

Stopped Stopped

Alarm Mode

(message)

No

Normal

operation Stopped

Normal

operation

Alarm Mode

(message)

No

Fixed

Normal

operation

Normal

operation

Alarm Mode

(message)

No

Fixed

Stopped Stopped

Alarm Mode

(message)

No

Normal

operation

Normal

operation

Normal

operation

No

Fixed

Stopped Stopped

Alarm Mode

(message)

Alarm Mode

(message)

No

Normal

operation

Normal

operation

Normal

operation

Normal

operation

Normal

operation Stopped

Alarm Mode

(message)

No

Fixed

Stopped Stopped

Alarm Mode

(message)

No

Fixed

Stopped Stopped

Alarm Mode

(message)

No

Open

(Off)

Fixed

Stopped Stopped

Alarm Mode

(message)

No

NO

(G30)

YES

(G30)

T0648.EPS

Alarm

record

Alarm description

Selection

(parameter

number)

Alarm

output

4-20 mA

output

Totali-
zation

Pulse

output

Display

unit

Occurring of
any alarm from
50 through 73

Span flow velocity setting
is 11 m/s or more

Span flow velocity setting
is 0.05 m/s or less

Totalization rate is 11000
pps or more

Totalization rate is
0.00005 pps or less

The condition [4-20 low
limit (J11) < 4-20 high
limit (J12)] is not satisfied.

The condition [No. 1 range
< No. 2 range < No. 3 range
< No. 4 range] is not
satisfied for multiple ranges.

The condition [High Alarm
(G11) – Low Alarm (G10) >
H/L Alarm Hys (G14)] or the
condition [High High Alarm
(G13) – Low Low Alarm
(G12) > H/L Alarm Hys
(G14)] is not satisfied.

Mass units have been
selected for Base Flow Unit
(C40) but density is set to 0.

Pulse rate is 11000 pps
or more with 50% duty
selection.

Pulse rate is 10000 pps
or more with 0.05 ms
selection.

Pulse rate is 5000 pps or
more with 0.1 ms selection.

Pulse rate is 1000 pps or
more with 0.5 ms selection.

Pulse rate is 500 pps or
more with 1 ms selection.

Pulse rate is 25 pps or
more with 20 ms selection.

Pulse rate is 15 pps or
more with 33 ms selection.

Pulse rate is 10 pps or
more with 50 ms selection.

Pulse rate is 5 pps or
more with 100 ms selection.

Pulse rate is 0.00005 pps
or less.

Measure Mode (C20) is
set to Enhanced DF
without selecting an
optional code
HF1 or HF2.

A value of 3000.1 mm or
more is set for Nominal
Size (C32).

73 Adh Set Err

Alarm Mode

(message)

No

The condition [Level:1<
Level:2<Level:3<Level:4]
is not satisfied for
adhesion diagnostic level.

Note: • Alarm is output only when F20: DO Function or F21: DIO Function is set to “Alarm Output.”

• The operation when “Open (Off) Act” is set for F22: DO Active Mode or “Open/Open Act“ is set for

F23: DIO Active Mode is shown in above table.

• 4-20mA output upon the occurrence of an alarm will be fixed at the value selected with G21: 4-20mA

Alarm Out.