Yokogawa AXFA14G/C User Manual

Page 36

Advertising
background image

IM 01E20C02-01E

6-7

6. PARAMETER DESCRIPTION

T0607-2.EPS

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

0 to 4

0 to 4

0

0 to 15

%

Auto Range Hys
(AUTO RNG HYS)

0 to 4

0 to 4

Reverse Span1
(REV SPAN1)

Forward Span4
(FWD SPAN4)

Forward Span3
(FWD SPAN3)

Reverse Span2
(REV SPAN2)

DIO Active Mode
(DIO ACT MODE)

Forward Span2
(FWD SPAN2)

DO Active Mode
(DO ACT MODE)

W

Closed(On) Act
Open(Off) Act

0 to 4

C40

/C41

C40

/C41

0.0001 to 32000

C40

/C41

0.0001 to 32000

C40

/C41

0.0001 to 32000

0.0001 to 32000

0.0001 to 32000

W

W

W

C40

/C41

W

W

W

Closed/Short Act
Open/Open Act

W

Sets flow rate span for reverse
No. 2 range


(SELF CHECK)

R

F60

Good
Error

F41

F32

F34

F40

F33

Sets flow rate span for forward
No. 2 range

Sets flow rate span for forward
No. 3 range

Selects whether DIO terminal
will be set to “Closed/Short
Active” or“Open/Open Active”.

Sets flow rate span for forward
No. 4 range

Sets hysteresis width for
forward/reverse switching

See “6.5 Alarm Function”.

Bi Direction Hys
(BI DIREC HYS)

Sets hysteresis width for
automatic range switching

Sets flow rate span for reverse
No. 1 range

1

2 %

F31

1

1

0 to 8

0

W

%

10 %

F22

F23

F30

1

Selects whether DO terminal
will be set to “On Active” or
“Off Active”.

Closed/Short Act

1

Closed(On) Act

(7) Item G (Menu G): Alarm Setting items

Menu G contains setting items relevant to alarm output, burnout, alarm record, etc.

T0608-1.EPS

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

0

0

R

W

W

W

No
Yes

0

0

Low Alarm
(LOW ALARM)

Low Low Alarm
(LO LO ALARM)

High Alarm
(HIGH ALARM)

H/L Alarm Hys
(H/L ALM HYS)

High High Alarm
(HI HI ALARM)

Alarm
(ALARM)

0

No
Yes

2.4mA or Less
4.0mA
Hold
21.6mA or More

4-20mA Alarm Out
(4-20 ALM OUT)

High
Low

No
Yes

-110 to 110

-110 to 110

W

-110 to 110

0 to 10

W

W

W

W

-110 to 110

W

%

%

%

%

%

Selects whether an electrode
adhesion alarm is to be specified
as an alarm.

G34

G33

Alm-Adhesion
(ALM-ADHESION)

No
Yes

G32

W

G31

G21

G13

G14

4-20mA Burn Out
(4-20 BURNOUT)

G22

Selects the current output during
alarm occurrence.

Sets level setting value for high-
high flow rate limit (HH)

Sets hysteresis width for high-
low flow rate limit alarm

G12

Sets level setting value for high
flow rate limit (H)

Displays the current output
during a CPU failure.

Sets level setting value for low-
low flow rate limit (LL)

Selects whether a flow rate high-
high or low-low alarm is to be
specified as an alarm.

No

Selects whether an empty pipe
alarm is to be specified as an alarm.

Selects whether a signal overflow
alarm is to be specified as an alarm.

Selects whether a setting alarm is
to be specified as an alarm.

G30

Yes

No

No
Yes

Yes

Yes

W

Alm-Sig Over
(ALM-SIG OVER)

Alm-Setting
(ALM-SETTING)

Alm-Emp Pipe
(ALM-EMP PIPE)

Alm-HH/LL
(ALM-HH/LL)

Sets level setting value for low
flow rate limit (L)

G11

-110

G00

G10

21.6mA or
More

110

5 %

-110

110

Advertising