IM 01E20C02-01E

6-5

6. PARAMETER DESCRIPTION

T0604-2.EPS

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

Mass Flow Density
(MASS DENSITY)

3

Velocity Check
(VELOCITY CHK)

Density Unit
(DENSITY UNIT)

R

m/s

0.000 to 99.999

C48

0.0001 to 32000

100

0 to 4

W

User Span Select
(USER SPN SEL)

Flow User Unit
(FL USER UNIT)

Flow User Span
(FL USER SPAN)

W

C45

W

0 to 32000

W

No
Yes

kg/m

3

lb/gal
lb/cf

0 to 4

8 alphanumeric
characters

W

C48

R

(SELF CHECK)

C49

C60

Good
Error

Sets density when mass flow rate
is selected (with units from C45).

Sets units for density when mass
flow rate is selected.

Selects whether or not special
units are used for flow rate units.

Sets the special flow rate units.

See “6.5 Alarm Functions”.

Sets span when using special flow
rate units.

0

Display of the span setting using
flow velocity (m/s).

No

kg/m

3

C44

C46

C45

C47

(4) Item D (Menu D): Total Setting items

Menu D contains setting items such as the totalization scale and the forward/reverse totalized values.

T0605.EPS

Item

Name

Display unit

(BRAIN)

Data range

Display unit

/BRAIN

Default value

(*): Indicated item

Units

R/W

Position

of decimal

point

Description

0

Pulse/s (*)

0 to 4

0

No
Yes

0

0

0

Total Decimal Pnt
(TL DECIMAL)

Ttl Set Val Lower
(TL SET VAL L)

Total Low Cut
(TOTAL LOWCUT)

Total Execution
(TOTAL EXEC)

Ttl Set Val Upper
(TL SET VAL U)

W

Ttl Switch Lower
(TL SWITCH LO)

Total Scale
(TOTAL SCALE)

Total Set
(TOTAL SET)

Total Unit
(TOTAL UNIT)

W

0 to 99

0 to 999999

0 to 99

W

0
1
2
3
4
5
6
7

0 to 32000

Start
Stop
Preset Total
Preset Rev Total

0 to 100

0 to 999999

Ttl Switch Upper
(TL SWITCH UP)

W

W

W

W

W

%

D10

(B30)

n Unit/P
u Unit/P
m Unit/P
Unit/P
k Unit/P
M Unit/P
Pulse/s

W

W

D30

D23

D31

D24

R

D60

(SELF CHECK)

D11

D22

Good
Error

D13

D12

D20

D21

D10

Executes “Start” or “Stop” of the
totalization function, or executes
“Preset Total” or “Preset Rev
Total”.

Sets the totalization switch value
in the lower 6 digits of the 8-digit
totalized value.

Sets the totalization preset value
in the upper 2 digits of the 8-digit
totalized value.

Sets the range in vicinity of 0%
within which the totalization
display will be halted.

Selects position of decimal point
for totalization display

Sets the totalization preset value
in the lower 6 digits of the 8-digit
totalized value.

Sets the totalization switch value
in the upper 2 digits of the 8-
digits totalized value.

See “6.5 Alarm Functions”.

Selects whether or not special
units are used as totalized units.

Sets the special totalized units.

W

0

0

3 %

0

Start

0

No

Ttl User Select
(TL USER SEL)

Ttl User Unit
(TL USER UNIT)

8 alphanumeric
characters

D00

0

Sets the flow rate per one pulse as
used for totalization display.
Linked with B31.

0 (*)

Selects the flow rate unit per one
pulse as used for totalization
display. Linked with B30.