2 alarm selection, Alarm selection -36, 2) display and output condition for process alarms – Yokogawa AXFA14G/C User Manual

Page 65

Advertising
background image

IM 01E20C02-01E

6-36

6. PARAMETER DESCRIPTION

6.5.2

Alarm Selection

The display and output differs depending on the alarm
levels. Certain types of alarm may or may not be
recognized as alarms, according to the settings of
certain parameters. The parameters that are relevant to
this function as follows.

[F20: DO Function] Setting of the function for the
DO status output terminal

[F21: DIO Function] Setting of the function for the
DIO status input/output terminal

[F22: DO Active Mode] Setting of the active mode
for DO terminal

[F23: DIO Active Mode] Setting of the active mode
for DIO terminal

[G21: 4-20mA Alarm Out] Setting of the current
output during an alarm occurring.

[G30: Alm-Setting] Alarm recognition of “Setting
Alarm”

[G31: Alm-Sig Over] Alarm recognition of “Signal
Overflow Alarm”

[G32: Alm-Emp Pipe] Alarm recognition of “Empty
Pipe alarm”

[G33: Alm-HH/LL] Alarm recognition of “HH/LL
Alarm” (Refer to the descriptions of G12 and G13 for
more details regarding HH and LL alarms.)

[G34: Alm-Adhesion] Alarm recognition of “Adhe-
sion Alarm”

[G41: Alm Record1] Alarm record1

[G43: Alm Record2] Alarm record2

[G45: Alm Record3] Alarm record3

[G47: Alm Record4] Alarm record4

(1) Display and output condition for system alarms

T0646.EPS

Alarm description

Alarm

output

4-20 mA

output

Totali-
zation Pulse

Display unit

Alarm

record

Normal

Normal

Normal Normal Display Mode

No

Closed

(On)

␮P Fault
EEPROM Fault

A/D(H) Fault

A/D(L) Fault

A/D(Z) Fault

Coil Open

EEPROM Dflt

Microprocessor(CPU)failure

EEPROM failure

A/D converter failure

Flowtube coil is open-circuit

EEPROM default values

Open

(Off)

Fixed

(G21 selection)

Stopped Stopped

Recorded

Alarm Mode

(display of system

alarm message)

Open

(Off)

0mA or

25mA

Stopped Indetermination

10

11

12

13

14

15

16

Note: • Alarm is output only when F20: DO Function or F21: DIO Function is set to “Alarm Output.”

• The operation when “Open (Off) Act” is set for F22: DO Active Mode, or “Open/Open Act“ is set for

F23: DIO Active Mode is shown in above table.

• 4-20mA output upon the occurrence of an alarm will be fixed at the value selected with G21: 4-20mA

Alarm Out.

*The output value is performed in accordance with the setting of the burnout switch. For information about

this switch, see Section 10.2.1.

Indeter-
mination

Indeter-
mination

(*)

(2) Display and output condition for process alarms

Alarm

description

Selection

(parameter

number)

Alarm

output

4-20 mA

output

Totali-
zation

Pulse

output

Display

unit

Alarm

record

30

31

32

33

Sig Overflow

Empty Pipe

HH/LL Alm

Adhesion Alm

Input signal error

Flowtube is not
filled with fluid

HH/LL Alarm

Electrode
adhesion alarm

T0647.EPS

Alarm Mode

(Message)

Alarm Mode

(Message)

Alarm Mode

(Message)

Alarm Mode

(Message)

Display Mode

Display Mode

Display Mode

Display Mode

Fixed

Continu-

ous (*)

Continu-

ous (*)

Continu-

ous (*)

Fixed

Fixed

Stopped

Continu-

ous (*)

Continu-

ous (*)

Continu-

ous (*)

Stopped

Stopped

Stopped

Continu-

ous (*)

Continu-

ous (*)

Continu-

ous (*)

Stopped

Normal

operation

Normal

operation

Normal

operation

Stopped

Recorded

No

Recorded

No

No

Recorded

No

Open

(Off)

Closed

(On)

Open

(Off)

Closed

(On)

Open

(Off)

Closed

(On)

Open

(Off)

Closed

(On)

YES

(G31)

NO

(G31)

YES

(G32)

NO

(G32)

YES

(G33)

NO

(G33)

YES

(G34)

NO

(G34)

Note: • Alarm is output only when F20: DO Function or F21: DIO Function is set to “Alarm Output.”

• The operation when “Open (Off) Act” is set for F22: DO Active Mode or “Open/Open Act“ is set for

F23: DIO Active Mode is shown in above table.

• 4-20mA output upon the occurrence of an alarm will be fixed at the value selected with G21: 4-20mA

Alarm Out.

*: Although outputs are continuous, output values are not guaranteed.