7. OPERATION VIA BRAIN TERMINAL (BT200)

7.3.2

BT200 Setting of Numeric-Type Data: Flow rate span

In this example, the flow rate span specified by the numeric-type parameter B23: Flow Span is changed from
100.000 l/min. to 120.000 l/m.

or

In this mode, new values can
be entered into the
highlighted field using the
alphanumeric keys.

In this example, the value
“120” is entered, press the

key.

F0708.EPS

MENU
A:DISPLAY
B:EASY SETUP
C:BASIC SETUP
D:TOTAL SET
E:PULSE SET
F:STATUS FUNC

HOME SET ADJ ESC

MENU
A:DISPLAY
B:EASY SETUP
C:BASIC SETUP
D:TOTAL SET
E:PULSE SET
F:STATUS FUNC

HOME SET ADJ ESC

PARAMETER
B10:LANGUAGE
English
B20:FLOW DAMPING
3.0s
B21:FLOW UNIT
l(Liter)

DATA DIAG PRNT ESC

PARAMETER
B22:TIME UNIT
/min
B23:FLOW SPAN
100.000l/min
B24:FLOW DECIMAL
l

DATA DIAG PRNT ESC

SETTING
B23:FLOW SPAN
120.000l/min

FEED NO OK

PARAMETER
B22:TIME UNIT
/min
B23:FLOW SPAN
120.000l/min
B24:FLOW DECIMAL
l

DATA DIAG PRNT ESC

SETTING
B23:FLOW SPAN
100.000l/min
+ 0

DEL CLR ESC

SETTING
B23:FLOW SPAN
100.000l/min
+ 120

DEL CLR ESC

SETTING
B23:FLOW SPAN
100.000l/min
+ 120

PRINTER OFF
F2:PRINTER ON

FEED POFF NO

After moving the cursor to
B23: FLOW SPAN, press

the key to access

Setting Screen (Parameter
Replacement Mode).

When Menu Screen (Major
Item Parameter Search
Mode) has been entered as
shown here, press the

key to move to

B: EASY SETUP.

When the cursor has been
moved to B: EASY SETUP.

Press the key to

access Parameter Screen
(Sub-Item Parameter
Search Mode).

The data will begin to flash
on and off: Press the

key once again

to confirm your entry.
In case of cancel, press the

( ) key.

NO

The changed setting for
flow rate span can now be
confirmed.

Press the ( ) key

to return to Menu Screen
(Major Item Parameter
Search Mode).

ESC

In the parameter list, the
parameter for setting of flow
rate span is B23: FLOW

SPAN. Press the

key four times to move the
cousor to B23.

(Note that the key

can be used to move the
cursor to the top of the next
screen.

The value for flow span has
been changed to
“120.000 l/min.”

Press ( ) key to

exit Setting Screen

(Parameter Replacement
Mode), and then the display
returns to Parameter
Screen (Sub-Item
Parameter Search Mode) of
Menu B items.
In case of redo of setting,

press the ( ) key

to return the Setting Screen
(Parameter Replacement
Mode).

OK

NO

( )