2.4 Setting Commands

SScan

Scan Interval

Sets the scan interval.

Syntax SScan,p1,p2

p1 Scan group (1)

p2 Scan interval (100ms, 200ms, 500ms, 1s,

2s, 5s)

Query

SScan[,p1]?

Example Set the scan interval to 1 second.

SScan,1,1s

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

SScanGroup

Scan Group

Registers a measurement channel in scan group 1.

Syntax SScanGroup,p1,p2,p3

p1 Unit number (0)

p2 Module number (0 to 9)

p3 Scan group (1)

1

Scan group 1

Query

SScanGroup[,p1[,p2]]?

Example Set the module whose module number is 2 in

scan group 1.

SScanGroup,0,2,1

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

SModeAI

AI Module

Sets the mode and A/D integration time of an AI module.

Syntax SModeAI,p1,p2,p3,p4

p1 Unit number (0)

p2 Module number (0 to 9)

p3 Mode

2CH

2 channel mode

10CH 10 channel mode

p4 AD integration time (Auto, 50Hz, 60Hz,

Common)

Query

SModeAI[,p1[,p2]]?

Example For the module whose module number is 2, set

the mode to 10CH and the AD integration time

to Auto.

SModeAI,0,2,10CH,Auto

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

• Scan intervals shorter than 1 s cannot be specified

if an electromagnetic relay scanner type (Type suffix

code: -T1) analog input module is in use (set up).

• Fixed to 10ch mode if an electromagnetic relay

scanner type analog input module is in use.

• You can set the parameters in the following

combinations.

Scan

Interval

Mode

(p3)

Integration time (p4)

Auto

50Hz

60Hz

Common

100ms

2CH

Yes

Yes

Yes

No

10CH

Yes

No

No

No

200ms

2CH

Yes

Yes

Yes

No

10CH

Yes

No

No

No

500ms

Yes

Yes

Yes

No

1s

Yes

Yes

Yes

Yes

2s

Yes

Yes

Yes

Yes

5s

Yes

Yes

Yes

Yes

SModeDI

DI Module

Sets the mode of a DI module.

Syntax SModeDI,p1,p2,p3

p1 Unit number (0)

p2 Module number (0 to 9)

p3 Mode (Normal, Remote)

Normal DI input

Remote Remote control input

Query

SModeDI[,p1[,p2]]?

Example Set the module whose module number is 2 as

a remote control input module.

SModeDI,0,2,Remote

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

• Only one module can be set to remote. If different

modules are set to remote numerous times, the last

module will be the remote module.

SScaleOver

Detection of Values That Exceed the

Scale

Sets how to detect measurement over-range.

Syntax SSclOver,p1

/P1 How to detect values that exceed the

scale

FREE Assume scale over-range when the

measurement range is exceeded.

OVER Assume scale over-range when

±105% of the scale is exceeded.

Query

SSclOver?

Example Assume scale over-range when the

measurement range is exceeded.

SSclOver,FREE