background image

2-17

IM 04L51B01-17EN

Commands and Responses

1

2

App

Description

• The RGB values for different colors are indicated in

the following table.

Color

R

G

B

Note

Red

255

0

0

Green

0

153

51

Blue

0

51

255

Blue violet

119

51

204 GX10/GP10

102

51

204 GX20/GP20

Brown

153

51

0

Orange

255

153

51

Yellow green

153

204

51

GX10/GP10

170

221

51

GX20/GP20

Light blue

119

170

221 GX10/GP10

153

204

255 GX20/GP20

Violet

204

102

204 GX10/GP10

221

153

221 GX20/GP20

Gray

153

153

153

Lime

102

255

0

Cyan

0

255

255

Dark blue

0

0

153

Yellow

255

255

0

Light gray

204

204

204

Purple

153

0

153 GX10/GP10

136

0

136 GX20/GP20

Black

0

0

0

Pink

255

17

153

Rosy brown

204

153

153

Pale green

153

255

153 GX10/GP10

187

255

153 GX20/GP20

Dark gray

102

102

102

Olive

153

153

0

Dark cyan

0

153

153

Spring green

0

204

153 GX10/GP10

0

221

119 GX20/GP20

SZoneIO

Waveform Display Zone

Sets the waveform display zone of an AI, DI, or DO

channel.

Syntax SZoneIO,p1,p2,p3

p1 Channel number

p2 Zone lower limit [%] (0 to 95)

p3 Zone upper limit [%] (5 to 100)

Query

SZoneIO[,p1]?

Example Set the waveform zone of channel 0001

waveform to 0% to 30%.

SZoneIO,0001,0,30

SScaleIO

Scale Display

Sets the scale display of an AI, DI, or DO channel.

Syntax SScaleIO,p1,p2,p3

p1 Channel number

p2 Scale display position (Off, 1 to 10)

p3 Number of scale divisions (4 to 12, C10)

Query

SScaleIO[,p1]?

Example Display the channel 0001 scale at display

position 1. Display four equally spaced main

scale marks.

SScaleIO,0001,1,4

SBarIO

Bar Graph Display

Sets the bar graph display of an AI, DI, or DO channel.

Syntax SBarIO,p1,p2,p3

p1 Channel number

p2 Bar display base position

Lower Lower

Center Center

Upper Upper

p3 Number of scale divisions (4 to 12)

Query

SBarIO[,p1]?

Example Display the measured values of channel 0001

on a bar graph with the center set as the base

position (Center). Display four equally spaced

main scale marks.

SBarIO,0001,Center,4

SPartialIO

Partial Expanded Display

Sets the partial expanded display of an AI channel

waveform.

Syntax SPartialIO,p1,p2,p3,p4

p1 Channel number

p2 Partial expanded On/Off (On, Off)

p3 Partial expanded boundary position [%] (1

to 99)

P4 Partial expanded boundary value (span

lower limit + 1 digit to span upper limit - 1

digit)

Query

SPartialIO[,p1]?

Example For channel 0001 whose measurement range

is 0 to 1.0000 V, display the measured value of

0.7500 V at the 50% position.

SPartialIO,0001,On,50,7500

Description

You cannot set this on a “Skip” channel. p2 is fixed to

Off.

If p2=Off, you cannot set p3 or subsequent

parameters.

P2=On can be specified when the difference between

the span upper and lower limits is 2 digits or greater.

SBandIO

Color Scale Band

Sets the color scale band of an AI channel.

Syntax SBandIO,p1,p2,p3,p4,p5,p6,p7

p1 Channel number

p2 Color scale band (Off, In, Out)

p3 R value of the color scale band RGB

colors (0 to 255)

P4 G value of the color scale band RGB

colors (0 to 255)

p5 B value of the color scale band RGB

colors (0 to 255)

p6 Upper limit of the color scale band display

(span lower limit to span upper limit)

2.4 Setting Commands

Advertising