13 general communication log (flog), 13 general communication log (flog) -69, 12 app – Yokogawa Touch Screen GP20 User Manual

Page 83

Advertising
background image

2-69

IM 04L51B01-17EN

Commands and Responses

1

2

App

2.10.13 General Communication Log (FLog)

The output in response to the command “FLog,General” is shown below.

Syntax

EA<crlf>

yyyy/mo/dd_hh:mm:ss_nn_uuu…u_fdmmm…m<crlf>

EN<crlf>

yyyy/mo/dd_hh:mm:ss Time of command Tx/Rx

yyyy

Year (1900 to 2099)

mo

Month (01 to 12)

dd

Day (01 to 31)

hh

Hour (00 to 23)

mm

Minute (00 to 59)

ss

Second (00 to 59)

nn

Connection ID

s0

Serial (general)

e0

Ethernet connection #0 (general)

e1

Ethernet connection #1 (general)

e2

Ethernet connection #2 (general)

uuu…u

User name (fixed to 20 characters. Unused character positions

are filled with spaces.)

f

Multiple command flag

Space

Single command

*

Multiple commands

d

Tx/Rx

>

Tx (command: connected instrument to

GX/GP)

<

Rx (Response: GX/GP to connected

instrument)

mmm…m

Message (fixed to 40 characters. Unused character positions are

filled with spaces.)

The GX/GP normally outputs the data that has been transmitted

or received as-is, but it sometimes outputs special messages.

Special messages are shown below.

(output)

Data output

(Over length)

Command length too long

(timed out)

Timeout

(disconnected)

Disconnection (occurs when an

Ethernet connection is disconnected)

2.10 ASCII Output Format