Commands and Responses

1

2

App

p9 Relay (DO channel) action on

acknowledge

Manual Output
Specifies the output value.
Syntax SRangeDO,p1,p2,p3,p4,p5,p6

p1 Channel number

p2 Output type (Manual)

p3 Span lower limit (0 to 1)

P4 Span upper limit (0 to 1)

p5 Unit (up to 6 characters, UTF-8)

p6 Energize or de-energize

Energize

Energize the relay (DO

channel) during output.

De_energize De-energize the relay

(DO channel) during

output.

Query

SRangeDO[,p1]?

Example Output an alarm on channel 0203. Set the

span lower limit to 0 and span upper limit to 1.

Specify energize operation, logic or operation,

and hold operation. Set the action on ACK to

Normal. Set the unit to “Unit.”

SRangeDO,0203,Alarm,0,1,Unit,Energ

ize,Or,Hold,Normal

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

• If p2=Manual, you cannot set p7 or subsequent

parameters.

• If p7=And or Or, you cannot set the reflash time.

SMoveAve

Moving Average

Sets the moving average of an AI channel.

Syntax SMoveAve,p1,p2,p3

p1 Channel number

p2 Enable or disable (Off, On)

p3 Number of samples (2 to 100)

Query

SMoveAve[,p1]?

Example Set the number of moving average samples for

channel 0002 to 12.

SMoveAve,0002,On,12

SBurnOut

Behavior When a Sensor Burns Out

Sets the behavior for when a burnout occurs on an AI

channel.

Syntax SBurnOut,p1,p2

p1 Channel number

p2 Burnout processing (Off, Up, Down)

Query

SBurnOut[,p1]?

Example Set the measured result to positive overflow

(Up) when a burnout is detected on channel

0001.

SBurnOut,0001,Up

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

SRjc

Reference Junction Compensation

Method

Sets the reference junction compensation method of an AI

channel.

Syntax SRjc,p1,p2,p3

p1 Channel number

p2 Mode

Internal Use the internal compensation

function.

External Use an external compensation

device.

p3 Compensation temperature

–200 to 800

–20.0 to 80.0°C

–40 to 1760

–40 to 1760°F

2531 to 3532

253.1 to 353.2K

Query

SRjc[,p1]?

Example Perform reference junction compensation of

channel 0003 using the internal compensation

circuit.

SRjc,0003,Internal

Perform reference junction compensation of

channel 0004 using an external compensation

device. Set the compensation temperature to

-2.3°C.

SRjc,0004,External,-23

Description

• You cannot use this command to configure settings

while recording is in progress.

• You cannot use this command to configure settings

while computation is in progress.

• If p2=Internal, p3 is invalid.

SAlarmIO

Alarm

Sets the alarm for AI and DI channels.

Do Not Set Alarms

Syntax SAlarmIO,p1,p2,p3

p1 Channel number

p2 Alarm number (1 to 4)

p3 Alarm on or off (Off)

Do Not Output Alarms
Syntax
SAlarmIO,p1,p2,p3,p4,p5,p6,p7

p1 Channel number

p2 Alarm number (1 to 4)

p3 Alarm on or off (On)

P4 Alarm type (H, L, DH, DL, RH, RL, TH, TL)

p5 Value

p6 Detection (Off, On)

2.4 Setting Commands