10 ascii output format, 1 most recent channel data (fdata), Ascii output format -57 – Yokogawa Touch Screen GP20 User Manual

Page 71: 1 most recent channel data (fdata) -57, Ascii output format, see, 12 app

Advertising
background image

2-57

IM 04L51B01-17EN

Commands and Responses

1

2

App

2.10 ASCII Output Format

This section explains the ASCII output format.

• In the following format descriptions, the terminator is denoted by “<crlf>.”

• One space (ASCII code : 0x 20) is denoted by an underscore (_). Consecutive spaces

are denoted by alternating underscores (_) and overscores (¯).

• An I/O channel is expressed as a four-digit number (e.g., 0102), a math channel is

expressed as “A” followed by a three-digit number (e.g., A015), and a communication

channel is expressed as “C” followed by a three-digit number (e.g., C120).

2.10.1 Most Recent Channel Data (FData)

The output in response to the command “FData,0” is shown below.

Syntax

EA<crlf>

DATE_yy/mo/dd<crlf>

TIME_hh:mm:ss.mmmt<crlf>

s_cccca

1

a

2

a

3

a

4

uuuuuufddddddddE-pp<crlf>

s_cccca

1

a

2

a

3

a

4

uuuuuufddddddddE-pp<crlf>

s_cccca

1

a

2

a

3

a

4

uuuuuufddddddddE-pp<crlf>

EN<crlf>

yy/mo/dd

Data time (year, month, day)

yy

Year (00 to 99)

mo

Month (01 to 12)

dd

Day (01 to 31)

hh:mm:ss.mmmt Data time (hour, minute, second, millisecond)

hh

Hour (00 to 23)

mm

Minute (00 to 59)

ss

Second (00 to 59)

mmm

Millisecond (000 to 999)

A period is inserted between the minute and millisecond.

t

Reserved (space)

s

Data status

N

Normal

D

Differential input

S

Skip

O

Over

E

Errors

B

Burnout

C

Communication channel error

cccc

Channel number (I/O channel, math channel, communication channel)

a

1

a

2

a

3

a

4

a

1

Alarm status (level 1)

a

2

Alarm status (level 2)

a

3

Alarm status (level 3)

a

4

Alarm status (level 4)

a

1

, a

2

, a

3

, and a

4

is set to one of the following:

H

High limit alarm

L

Low limit alarm

h

Difference high limit alarm

l

Difference low limit alarm

R

High limit on rate-of-change alarm

r

Low limit on rate-of-change alarm

T

Delay high limit alarm

t

Delay low limit alarm

Space

No alarm

uuuuuu

Unit (fixed to 10 characters. Output flush left. Unused character positions

are filled with spaces.)

mV_¯_¯_¯_¯ mV