DMU DIGITAL METERS UNIT FOR NXAMP

DMU Digital Meters Unit for NXAMP

The Digital Meters Unit (DMU) is a 1U 19” accessory for NXAMP4x1 and NXAMP4x4

powered TDcontrollers.

This device is intended to monitor the input level on the four analog inputs and the four

network inputs (from an Ethersound™ or Dante™ network if expansion board is fitted) of

the NXAMP powered TDcontroller. Network ports status can be monitored as well.

Front panel description

1

2

3

(1) Analog inputs with link

These XLR-3 connectors are intended to connect the analog audio source (analog outputs

of a mixer for example) to the NXAMP input. Both XLR3 male and female are in parallel for

each input (marked A to D), allowing to link several DMU together.

(2) Input view meter

Fore each input a view-meter is installed between the two XLR. This meter shows the audio

level with a maximum of 0 dBr (meaning the clip of the input stage witch is +28 dbU). The

scale is the following:

Number of LEDs ON

NXAMP A/D out level

8 0

dBr

7 -6

dB

6 -12

dB

5 -18

dB

4 -24

dB

3 -30

dB

2 -36

dB

1 -42

dB

0 <-42

dB


(3) Network inputs

These Ethercon® connectors can be used either when NXES104 or NXDT104 cards are

fitted into the NXAMP. Network status LEDs are fitted next to each network port, but there

meaning is slightly different depending on the card fitted.