APPENDIX B: HOW IS MEASURED THE AMPLIFIER POWER?

measure directly the output voltage on the screen.

Precision of the measurement

• All the measurement tools (Digital scope and distortion analyzer) have been

recently calibrated (less than one year).

• We’ve made some measurements on some batch of NXAMP to have a clear idea of

the precision of the amplifier itself, from one unit to the other (small differences in

the manufacturing of the custom transformer of the larges power supplies are the

main factor for having different power capability).

• The precision on the dummy loads has also been checked with a calibrated

ohmmeter.

Due to all this tolerances, we can compute a value for the power output of each channel of

the amplifier in a precision of (+/- 10 %).

Measurement method

The input signal is a burst sine wave at 1 KHz, for 20 ms, every 500 ms. We increase the

input level up to reaching 1 % THD+N on the distortion analyzer. We measure the signal

with the scope cursor as shown in the picture bellow:

The last one wave of burst signal
shall be measured.

Close-up
The center of the emission line shall
be adopted as the measurement value.

Signal

20 msec

1 msec

500 msec

Vburst

Cursor

We do 4 measurements for each output, so we do 16 measurements per unit. Then we

average on 4 units of NXAMP4X1C or NXAMP4X4C.

Then we redo the same with 4 units of NXAMP4X1U or NXAMP4X4U, mains being 120 Volts

(+2, -0 Volts at 60 Hz).

Finally we average all the measurements and this is the values which are written in the

datasheet of the NXAMP Powered TDcontrollers.