(6) GPIO port

This GPIO port is used for interfacing the amplifier to security system, or to allow a basic

remote control of the unit. NEXO DMU (Digital Meters Unit) device also connects here.

(7) Rear end mounting holes

If the NXAMP is to be rack mounted and transported frequently, be sure to support the

rear end of the unit with mounting hardware that matches the size of the rack used.

Basic functions

Reset

You can reset the unit without powering off by simultaneously depressing buttons A, B &

‘Select CH1’ for 3 seconds at least.

0. FLAT - NO PROTN.

[4 ch amplifier]

~

~

(For 3 seconds)

Selecting cabinet family

Simultaneously depressing A & B buttons at power up or during device RESET accesses the

System Change menu. Keep the A & B Buttons held until Load revision disappears from

screen (approx. 2 seconds). This will allow the selection of any cabinet in any family. Using

the rotary encoder, scroll through the configurations and press B to load the required

settings.