SETTING-UP ADVICE

Setting-Up Advice

Earth connection

WARNING! THIS APPLIANCE MUST BE EARTHED.

The green and yellow wire of the mains cord must always be connected to an installation

safety earth or ground. The earth is essential for personal safety as well as the correct

installation of the system, and is internally connected to all exposed metal surfaces. Any

rack framework into which this unit may be mounted is assumed to be connected to the

same grounding circuit.

Mains setting

NEXO NXAMP Powered TDcontrollers exists under two references for NXAMP4x1 and three

references for NXAMP4x4:

NXAMP Reference

Mains Voltage

Mains current

NXAMP4x1U

100 to 120 Volts

Max 20 Amps

NXAMP4x1C

220 to 240 Volts

Max 10 Amps

NXAMP4x4U

100 to 120 Volts

Max 2x 30 Amps

NXAMP4x4C

220 to 240 Volts

Max 2x 16 Amps

110 to 120 Volts

Max 2x 30 Amps

NXAMP4x4W

220 to 240 Volts

Max 2x 16 Amps

Each model applies to various safety standards only when use with the correct mains

voltage. Therefore, the amplifier won’t start (or will stop working) if the mains voltage is

getting out of the following min and max limits:

NXAMP Reference

Mains Minimum Voltage

Mains Maximum Voltage

NXAMP4x1U or

NXAMP4x4U

60 Volts

150 Volts

NXAMP4x1C or

NXAMP4x4C

150 Volts

288 Volts