9) channel indicators, 10) air intakes, 11) screw holes for handles – Nexo NUAR User Manual

Page 17: Hannel indicators, Ir intakes, Crew holes for handles

Advertising
background image

QUICK START

(9) Channel indicators

For each channel, you have three LEDs indicator. The ‘Sense’ LED will light to green when a

certain level of current is detected on the output, meaning that a cabinet is connected and

that some signal is flowing to it. The ‘Protect’ LED will light to yellow if the TDcontroller is

applying a VCEQ protection on that channel (see further for details). The ‘Peak’ LED will

light to red to indicate that the peak limiter is working to protect the amplifier.

(10) Air intakes

The NXAMP uses forced-air cooling. The variable speed cooling fan draws air in from the

front and exhausts it through the rear. Please be sure that you do not block the air intakes

or exhaust vents.

Please be sure not to mix inside the same rack amplifiers with opposite air flow.

(11) Screw holes for handles

These four screw holes are for the optional handles. Fix the handles to the amplifier using

the flat-head screws included with the handles (Screw driver or key TORX X20 is needed).

NB: Separate handle models exist for NXAMP4x1 and NXAMP4x4

PAGE 17 OF 140