Select your cabinet set-up

In the Options menu, choose Systm Config, and you will be able to choose among the

different set-ups within the same cabinet family. (i.e. you don't have to modify the

amplifier to cabinet wiring). Press All button and all setups will be available for selection.

Using the amplifier without the TDcontroller functionality

If you want to use the amplifier without the TDcontroller, just choose the “FLAT mode”

setup. In this mode, no EQ and no protection is applied to the cabinets. Please note that

the amplifier will still have 0.5 ms analog input to analog output latency in that mode

(warning, this latency is not the same than a NX242 TDcontroller in flat mode, see

introduction for compensating values).

In Flat mode, full amplifier digital protections are still available, and some functionality like

volume control, input patching, mute, delay, gain and ArrayEQ are working. Remote

control can be used as well.

Back to default

Startup the amplifier with the ‘Select CH1’ button down and you will have the possibility

to reset the settings to default (except if the local controls have been locked, see further).

Auto save

The current set-up is automatically saved three seconds after the last change of a

parameter. At power up the last saved settings are restored.

Enter the download mode

Keep the ‘Mute 1’ button down during boot up will enter the download mode. See further

for connection to the computer and download software (Nxwin) description.