Using the nxamp without a rack, Fuses, Electromagnetic environments – Nexo NUAR User Manual

Page 26: Analogue input signal cables, Sing the, Nxamp, Without a rack, Uses, Lectromagnetic environments, Nalogue input signal cables

Advertising
background image

SETTING-UP ADVICE

Using the NXAMP without a rack

If you do not put the NXAMP into a rack, then it is mandatory to use the four rubber pads

enclosed into the amplifier carton box. These auto adhesive pads should be stuck on each

corner of the bottom of the amplifier. Without these rubber pads, some internal

components can be damaged when there is a shock (for example dropping the amplifier on

a table).

Fuses

The fuses provided in the unit will not blow during normal operation. If one of the

fuses blows it means that the Powered TDcontroller has malfunctioned. This fuse must only

be changed by NEXO certified service personnel. In any case do not replace the fuse with a

non-certified NEXO fuse, as this will invalidate the NEXO warranty.

CAUTION!

This servicing instruction is for use by qualified service personnel only. To reduce the risk of

electric shock, do not perform any servicing other than that contained in the operating

instructions unless you are qualified to do so.

Electromagnetic environments

The emission (this word describes all types of electromagnetic noise radiated by the

equipment) requirements which have been applied to Nexo’s Powered TDcontrollers are the

stringent requirements of the “Commercial and light industrial environment” of the product

family EMC standard for emission.

The immunity (this word describes the ability to cope with electromagnetic disturbance

generated by other items and natural phenomena) requirements that we have considered

exceed those applicable to the “Commercial and light industrial environment” of the

product family EMC standard for immunity. In order to provide a further safety margin, we

recommend that you do not operate the Powered TDcontrollers in the presence of

electromagnetic interference exceeding half of the limits found in this standard.

These two EMC standards are those applicable to pro-audio equipment for the

implementation of the “EMC directive”.

Analogue input signal cables

Analogue signals should be connected to the input ports of the NXAMP Powered

TDcontroller via shielded twisted pair or Starquad cable fitted with XLR connectors on the

NXAMP side. We recommend the use of low transfer impedance cables with a braided

shield and transfer impedance below 10 mΩ/m.

The NXAMP Powered TDcontroller is intended to be used with symmetrical (balanced)

sources (for instance a mixer, see figure bellow). You can see that the TDcontroller

provides a low impedance path between pin 1 of its XLR connectors and its chassis. The