Geometrical alignment, Eometrical alignment, Specified meters or feet). • r – Nexo NUAR User Manual

Page 75: And r

Advertising
background image

INSTALLATION RECOMMENDATIONS

(see example below)

We recommend that the system is adjusted so that arrivals from MAIN SYSTEM array and

SUB speakers are coincident at a fairly distant listening position (typically further than the

mixing position).

Geometrical alignment

In the example below,

r

1

being the smaller distance from MAIN SYSTEM array to listener

position, and

r

2

being the smaller distance from SUB to listener position, the distance

difference is then

r

1

r

2

(specified meters or feet).

r

1

>

r

2

, the delay should be set on the SUB NXAMP Powered TDcontroller(s).

r

1

<

r

2

, the delay should be set on the MAIN SYSTEM NXAMP Powered

TDcontroller(s)

To convert the result in time delay (specified in seconds), apply:

∆t = (

r

1

-

r

2

)/C

r

1

and

r

2

in meters, C (sound speed) ≈ 343 m/S.

The delay parameter is set in MENU “Delay” (See above).

However, it is a safe practice to double-check geometrical alignment with a proper

acoustical measurement tool.

Measuring and aligning phase in the overlapping region

Microphone must be set on the ground, at a fairly distant listening position (typically

further than the mixing position).

Phase must be measured with a wrapped display, and measurement must be properly

windowed on signal arriving time (same window for SUB and MAIN SYSTEM). When

measurement is synchronized to the system-microphone distance, phase can be clearly

1200 mm

[47.24"]

750 mm
[29.53"]

750 mm
[29.53"]

1200 mm

[47.24"]

750 mm
[29.53"]

750 mm
[29.53"]

1200 mm

[47.24"]

750 mm
[29.53"]

750 mm
[29.53"]

r

2

r

1

PAGE 75 OF 140

Advertising