APPENDIX B: HOW IS MEASURED THE AMPLIFIER POWER?

Appendix B: How is measured the amplifier power?

This part of the document describes the setup we have used to measure the power

available on the NXAMP Powered TDcontroller outputs for each load (8, 4 and 2 Ohms).

General description of the setup

The drawing bellow shows the setup used to measure the output power:

y

& Kjær

Audio Generator

with

Distortion Analyzer

Digital Scope

NXAMP Under Test

4x Dummy

Loads

The Audio Generator with distortion analyzer is used to generate test signals. It analyzes

the output of the amplifier to measure the THD+N, thus we can know when we reach the

clip of the amplifier with a certain value of distortion (typically 1 %).

The NXAMP under test is powered through a monitored power supply with voltage adjusted

to 230 Volts (+2/- 0 Volts) and 50 Hz.

The 4 analog inputs of the NXAMP Powered TDcontroller are linked together so all the

channels are fed. DSP setup is “FLAT – NO PROTN”, meaning that no EQ or gain is applied

and that only the amplifier protections are working. The volume is set to 0 dB attenuation.

Each output of the amplifier is connected to a dummy load (8, 4 or 2 Ohms). On one

channel, we loop the voltage back to the distortion analyzer and to a digital scope, to

PAGE 136 OF 140