NXWIN4 SOFTWARE FOR NXAMP FIRMWARE UPGRADE

(2) Ethersound™ IN port

This port can be used to upgrade the NXAMP when a NXES104 board is fitted. You can

either directly connect the computer to this port or reach the NXAMP through the

Ethersound™ network. If several NXAMP are connected together in an Ethersound™

network, you can upgrade automatically one after the other.

(3) RS-232 Serial port

This port can be used with or without NXES104/NXDT104 board fitted inside the amplifier.

However, we recommend using one of the network ports if a NXES104/NXDT104 board is

fitted because NXwin4 can also upgrade the firmware of the network card itself (what

cannot be done through the serial port).

(4) Dante™ primary, secondary or remote port

These ports are equivalent for firmware download, you can use any of them. Several amp

with NXDT104 cards can be linked through the available ports, and even NXAMP with

NXES104 board can be connected (through their Remote ES100 port) allowing to upgrade

at once mixed inventory of NXAMP.

Put the NXAMP in download mode

That means power the unit “ON” while having the ‘mute 1’ button down.

(1) Hold the mute 1 button down, and keep it down.

(2) Turn ON the NXAMP Powered TDcontroller.

The NXAMP screen will display the revision of the boot loader, and then the following

message will appear: