Display mode – In-Situ Win-Situ 4 / Pocket-Situ 4 Operators Manual User Manual
Page 35
![background image](/manuals/367719/35/background.png)
35
0031510 rev. 003 11/04
DISPLAY MODE
Select one of the following. Subsequent screens
will be tailored to your choice.
• Pressure Head displays the raw pressure
exerted by the column of water above the
pressure sensor, in kiloPascals, pounds per
square inch, bars, or kilograms per square
centimeter. If you choose this mode, click
Finish to end the Wizard.
• Depth converts the pressure of the water
column to a depth reading, in meters,
centimeters, feet, or inches.
• Level - Surface: Commonly used for surface
water elevations. Data file readings are
“positive up.” Increasing water levels will result
in increasing readings. Decreasing water
levels correspond to decreasing readings.
• Level - Top Of Casing: Commonly used for
drawdown in groundwater wells. This mode is
“positive down.” Decreasing water levels
correspond to increasing readings, because
the water level is getting further from the top of
the well casing. Increasing water levels result
in decreasing readings.
SECTION 5: PRESSURE SETUP
Depth