3-5 “setting 05” vt ratio, Default value – KYORITSU 6300 Instruction Manual User Manual

Page 35

Advertising
background image

4. 9

MODEL6300

Section 4 Setting

MODEL6300

‣ ‧•⁈ ‥• •⁈ 
•• ⁈

‣ ⁂․ ⁉ ‣ ⁂‥ ⁉ ‥⁂ ‥⁉ ‥ ⁂…⁉

‧ ″

‣ •″

․ •″

‧• ″

‣•• ″ ․•• ″ ‧• •″ ‣• ••″


4-3-5 “Setting 05” VT ratio

For the detailed information about VT ratio, refer to “5-3 VT/CT” in
this manual.

Setting range

1 ~ 10000

Default value

1

* Using the

Cursor

key whilst in the selection screen, select “Setting 05”.

* Press the

ENTER

key to enter setting change mode.

* The rightmost digit of previous setting (or default value: 00001) flickers.
* Change the number with the

Cursor

key, and then press the

ENTER

key.











Function of

Cursor

keys

To select the desired digit.

To change the value of selected digit.

When VT ratio is set to other than 1, “ ” mark appears on each
measurement screen.

NOTE

* When 0 is set as a VT ratio, it is automatically changed to 1.

In case that a value of 10000 or more is set, it is automatically changed to
10000.

* If a value cannot be set as a VT ratio, a message “ ” is displayed

on the LCD, and the value returns to the previous set value.

(Voltage range “Setting 02”) x 120% x (Current range “Setting 03”) x 120%

x (VT ratio ) x (CT ratio “Setting 06”) > 9999G (G=10

9

)




‣ ‧

‣ ‧• ⁈

• ⁈ ‥• •

• •⁈ 
 •


 •• ⁈

• ⁈

‣ ⁂

‣ ⁂ ․⁉ ‣ ⁂

‣ ⁂‥ ⁉

‥ ⁉ ‥ ⁂

‥ ⁂‥ ⁉

‥ ⁉ ‥⁂ …⁉

‧″

‧″

‣ •″

•″

․ •″

•″

‧ •″

•″

‣•

‣• •″

•″ ․ ••

•• ″ ‧•

‧• •″

•″ ‣ ••

•• •″

•″