HA-Fabric Manager user guide 211

Domain IDs must be in

the range of 1 to 31.

Domain IDs entered in the

Configure Preferred Paths

dialog box must fall in a

specific range.

In the Configure Preferred Paths

dialog box, change the number in

the Destination Domain ID field to

a number between 1 and 31,

inclusive.

Duplicate Community

names require identical

write authorizations.

Duplicate community

names are entered at the

Configure SNMP dialog

box, and have different

write authorizations.

Delete the duplicate community

name or make the write

authorizations consistent.

Element Manager error

<number>.

The Element Manager

encountered an internal

error and cannot

continue.

Contact the next level of support to

report the problem.

Element Manager

instance is currently

open.

A Element Manager

window is currently open.

Informational message only.

Enterprise Fabric Mode

will be disabled if any of

the following parameters

are disabled: Insistent

Domain ID, Rerouting

Delay, Domain RSCNs.

Do you want to continue?

You attempted to disable

these parameters in the

Configure Switch

Parameters dialog box

while the switch was

online, but Enterprise

Fabric Mode (SANtegrity

Binding feature) is

enabled.

Click Yes if you want to continue,

and disable Enterprise Fabric

Mode.

Error retrieving port

information.

An error occurred at the

Element Manager while

retrieving port

information because the

Ethernet link is down or

busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Error retrieving port

statistics.

An error occurred at the

Element Manager while

retrieving port statistics

because the Ethernet link

is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Error stopping port

diagnostics.

An error occurred at the

Element Manager while

attempting to stop port

diagnostics from running

because the Ethernet link

is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Table 24