HP StorageWorks 2.32 Edge Switch User Manual

Page 217

Advertising
background image

HA-Fabric Manager user guide 217

Log is currently in use.

Access to the log is

denied because the log

was opened by another

instance of the Element

Manager.

Retry the operation later. If the

condition persists, contact the next

level of support.

Loopback plug(s) must be

installed on ports being

diagnosed. Press Next to

continue.

External loopback

diagnostics require an

optical loopback plug to

be installed.

Ensure that an optical loopback

plug is installed in port optical

transceiver before running external

wrap diagnostic testing.

Maximum number of

versions already

installed.

The number of firmware

versions that can be

defined to the HAFM

application’s firmware

library (eight) was

reached.

Delete an existing firmware version

before adding a new version.

No file was selected.

Action requires the

selection of a file.

Select a file.

No firmware version file

was selected.

A file was not selected in

the Firmware Library

dialog box before an

action, such as modify or

send was performed.

Click on a firmware version in the

dialog box to select it, then

perform the action again.

No firmware versions to

delete.

There are no firmware

versions in the firmware

library to delete,

therefore the operation

cannot be performed.

Informational message only—no

action is required.

Nonredundant director

must be offline to install

firmware.

For directors, if the

director has only one CTP

card, the director must be

set offline to install a

firmware version.
For switches, since the

switch has only a single

CTP card, it must be

offline to initiate a

firmware installation.

Note that the CTP card is

an internal component

and not a FRU.

Set the director or switch offline

and install the firmware.

Table 24

Element Manager Messages (continued)

Message

Description

Action

Advertising