HP StorageWorks 2.32 Edge Switch User Manual

Page 220

Advertising
background image

Informational and error messages

220

SNMP trap address not

defined.

If an SNMP community

name is defined, a

corresponding SNMP

trap recipient address

must also be defined.

Enter a corresponding SNMP trap

recipient address.

Stop diagnostics failed.

The test is already

running.

Diagnostics for the port

was not running and

Stop was selected on the

Port Diagnostics dialog

box. Diagnostics quit for

the port for some reason,

but the Stop button

remains enabled.

Verify port operation. Retry

diagnostics for the port and

choose Stop from the dialog box.

If problem persists, contact the next

level of support.

Stop diagnostics failed.

The test was not running.

This action failed

because the test was not

running.

Informational message.

Switch Binding was

removed from attached

devices that are also

participating in Port

Binding. Please review

the Port Binding

Configuration.

The device WWNs were

removed from the

director's Switch

Membership List

(SANtegrity Binding

feature), but you should

note that one or more of

these devices still has

security control in port

binding.

Verify that the security level for

each device is as required by

reviewing the Bound WWN list in

the Configure Ports dialog box.

System diagnostics

cannot run. The

Operational Status is

invalid.

System diagnostics

cannot run on switches

with failed ports

Replace failed ports.

The add firmware

process has been

aborted.

You aborted the process

to add a firmware version

to the HAFM appliance’s

firmware library.

Verify the firmware addition is to

be aborted, then click OK to

continue.

Table 24

Element Manager Messages (continued)

Message

Description

Action