HP StorageWorks 2.32 Edge Switch User Manual

Page 219

Advertising
background image

HA-Fabric Manager user guide 219

Port diagnostics cannot

be performed on an

inactive port.

This displays when port

diagnostics is run on a

port in an inactive state.

Run the diagnostics on an active

port.

Port speeds cannot be

configured at a higher

rate than the director

speed.

This displays when you

configure a port to 2

Gb/sec and the director

speed is set to 1 Gb/sec.

Set the director speed to 2 Gb/sec

in the Configure Switch Parameter

dialog box.

Port numbers must be in

the range of 0 to xxx.

When configuring

Preferred Paths, source

ports and exit ports must

be in the range of ports

for the switch being

configured.

In the Configure Preferred Paths

dialog box, change the numbers in

the Source Port and Exit Port fields

to fall within the port count of the

switch on which you are

configuring paths.

Preferred Paths can not

be enabled until the

Domain ID is set to

Insistent. Disable

Preferred Paths, then

configure Switch

Parameters.

If the switch’s domain ID

has not been set to

Insistent, the user is not

allowed to activate the

Preferred Path

configuration with the

Enable Preferred Paths

check box selected.

Close the Configure Preferred

Paths dialog box and click

Configure > Operating Parameters

> Switch Parameters. In the

Configure Switch Parameters

dialog box, click the Insistent

check box.

R_A_TOV must be

greater than E_D_TOV.

R_A_TOV must be

greater than E_D_TOV.

Change one of the values so that

R_A_TOV is greater than E_D_TOV

Resource is unavailable.

The specified operation

cannot be performed

because the product is

unavailable.

Verify that the Ethernet connection

between the HAFM appliance and

the director is up or available.

Resource is unavailable.

The specified operation

cannot be performed

because the product is

unavailable.

Verify that the HAFM

appliance-to-product link is up. If

the link is up, the HAFM appliance

may be busy. Try the operation

again later.

SANtegrity Feature not

installed. Please contact

your sales representative.

You selected Switch

Binding from the

Configure menu, but the

optional SANtegrity

Binding feature is not

installed.

Install the SANtegrity Binding key

through the Configure Feature Key

dialog box before using Switch

Binding features.

Send firmware failed.

A firmware download

operation failed.

Retry the firmware download

operation. If the problem persists,

contact the next level of support.

Table 24

Element Manager Messages (continued)

Message

Description

Action