FanAm MD60 AC Drive User Manual

Page 61

Advertising
background image

Parameter Descriptions

9-11

Sets the trip point for the output relay if the value of Relay Output
Select (A055) is 6, 7, 8, 10 or 20. See table 9.1.

Sets the rate of acceleration for speed increases if A051 or A052 is
set to option 1 (Accel 2 and Decel 2). See figure 9.3.

Maximum Frequency / Accel Time = Accel Rate.

A056 Relay Output Level

Range:

0.0 to 9999 (see table 9.1)

Default:

0.0

See also:

A055

32

Table 9.1 – Trip Points for Digital Output Relay

A055 Setting

Range

6 (Above Frequency)

0 to 240 Hz

7 (Above Current)

0 to 180%

8 (Above DC Bus Volts)

0 to 815 V

10

0 to 100%

20

0 to 1

A067 Accel Time 2

Range:

0.0 to 600.0 sec

Default:

10.0 sec

See also:

P039

Figure 9.3 – Accel Time 2 (A067)

Speed

0

Time

[Maximum Freq]

[Accel Time]

[Decel Time]

0

Acceleration

De

ce

lerat

ion