Parameter Descriptions

9-21

Enables/disables a software instantaneous (within 100 ms) current
trip.

Scales the value displayed by Process Display (d010).

Output Frequency x Process Factor = Process Display

1 = Reset Fault: Clears the active fault and resets the drive.

2 = Clear Buffer: Clears fault codes from parameters d007 through
d009.

Protects parameters against change by unauthorized personnel.

A098 SW Current Trip

Range:

0.0 to (Drive Rated Amps x 2)

Default:

0.0 (Disabled)

See also:

N/A

A099 Process Factor (Display Scaling)

Range:

0.1 to 999.9

Default:

30.0

See also:

d010

A100 Fault Clear

Range:

0 = Ready/Idle
1 = Reset Fault
2 = Clear Buffer (d007 - d009 [Fault x Code])

Default:

0 = Ready

See also:

d007 - d009

A101 Program Lock

Range:

0 = Unlocked
1 = Locked

Default:

0 = Unlocked

See also:

N/A