Parameter Descriptions

9-29

The output frequency scaled by A099 (Process Factor).

Output Frequency x Process Factor = Process Display

Displays the active source of the Start Command and Speed
Reference, which are normally defined by the settings of P036
(Start Source) and P038 (Speed Reference), but may be overridden
by digital inputs. Refer to the flowcharts in section 6.6 and 6.7 for
details.

d010 Process Display

Range:

0.00 to 99999

Default:

Read Only

See also:

d001, A099

32

d012 Control Source

Range:

0 to 9
See figure 9.11.

Default:

Read Only

See also:

P036, P038, A051, A052

Figure 9.11 – Control Source (d012) Bit Definitions

Start Command

Digit 0

0 = Keypad
1 = 3-Wire
2 = 2-Wire
3 = 2-Wire Level Sensitive
4 = 2-Wire High Speed
5 = RS485 Port
9 = Jog

Speed Reference

Digit 1

0 = Drive Potentiometer
1 = A069 (Internal Frequency)
2 = 0-10V Input
3 = 4-20mA Input
4 = A070-A073 (Preset Frequency x). A051-A052
(Digital InX Select) must be set to 4.
5 = RS485 port
9 = Jog Frequency

Reserved

Digit 2

Reserved

Digit 3