Parameter Descriptions

9-27

9.3

Display Group Parameters

The output frequency present at terminals T1, T2, and T3 (U, V, and
W).

The value of the active frequency command. Displays the
commanded frequency even if the drive is not running.

Important:

The frequency command can come from a number of
sources. Refer to section 6.5, Start and Speed
Reference Control, for more information.

The output current present at terminals T1, T2, and T3 (U, V, and
W).

The output voltage present at terminals T1, T2, and T3 (U, V, and
W).

d001 Output Frequency

Range:

0.0 to Maximum Frequency

Default:

Read Only

See also:

d002, d010, P034, P035

d002 Commanded Frequency

Range:

0.0 to Maximum Frequency

Default:

Read Only

See also:

d001, P034, P035, P038

d003 Output Current

Range:

0.00 to Drive Rated Amps x 2

Default:

Read Only

See also:

N/A

d004 Output Voltage

Range:

0 to Drive Rated Volts

Default:

Read Only

See also:

P031, A084, A088