FanAm MD60 AC Drive User Manual

Page 62

Advertising
background image

9-12

MD60 AC Drive User Manual

Sets the rate of deceleration for speed decreases if A051 or A052 is
set to option 1 (Accel 2 and Decel 2). See figure 9.4.

Maximum Frequency / Decel Time = Decel Rate

Provides the frequency command to the drive when Speed
Reference (P038) is set to 1 (Internal Frequency). When enabled,
this parameter will change the frequency command in “real time”

using the integral keypad

keys when in program mode.

A068 Decel Time 2

Range:

0.1 to 600.0 sec

Default:

10.0 sec

See also:

P040

Figure 9.4 – Decel Time 2 (A068)

Speed

0

Time

[Maximum Freq]

[Accel Time]

[Decel Time]

0

Acceleration

De

ce

lerat

ion

A069 Internal Frequency

Range:

0.0 to 240 Hz

Default:

0.0 Hz

See also:

P038

Advertising