FanAm MD60 AC Drive User Manual

Page 80

Advertising
background image

9-30

MD60 AC Drive User Manual

The status of the control terminal block control inputs.

Important:

Actual command may come from a source other than
the control terminal block.

The status of the control terminal block digital inputs.

d013 Control Input Status

Range:

0 = Input Present
1 = Input Not Present
See figure 9.12

Default:

Read Only

See also:

N/A

1

The stop input must be present to start the drive. When this

bit is a 1, the drive can be started. When this bit is a 0, the
drive will stop.

Figure 9.12 – Control Input Status (d013) Bit Definitions

Start / Run FWD Input (I/O Terminal 02)

Digit 0

Direction / Run REV Input (I/O Terminal 03)

Digit 1

Stop Input

1

(Control Terminal 01)

Digit 2

Reserved

Digit 3

d014 Digital Input Status

Range:

0 = Input Not Present
1 = Input Present
See figure 9.13.

Default:

Read Only

See also:

A051, A052

Figure 9.13 – Digital Input Status (d014) Bit Definitions

Digital In1 Sel (I/O Terminal 05)

Digit 0

Digital In2 Sel (I/O Terminal 06)

Digit 1

Reserved

Digit 2

Reserved

Digit 3