Pcs. Component name

1

Motherboard

2 Weighing

module

3

Round ferrite core

4

Ferrite core


4. While installing the module in the plastic socket on the main board turn

you attention to the position of the module (see the figure below),

5. The strain gauge cable led through additional gland PG7 situated on the

back wall next to the gland of the main platform cable;

6. Pull a ferrite core on the cable (appropriate internal diameter);
7. Wind wires of the cable on the round ferrite core (5 coils);
8. The wires solder accordingly to pads on the PCB. USE A SOLDERING

IRON (not a solder gun with a transformer);

9. Connect cable IN/OUT to group of conductors (undo band clips fastening

group of conductors, lay the cable and clamp band clips – multiple use
band clips);

10. Assembly cover of indicator casing.



34.2. Additional 8 inputs / 8 outputs module

8 inputs / 8 outputs PCB - WE 8


This module can be connected inside the weighing terminal. Its task is
to expand the functionality of terminal for 8 inputs and 8 outputs freely
configurable.

- 122 -