Installation instructions – L.B. White Pilot User Manual

Page 13

Advertising
background image

General Information

Installation

Instructions

1. Read all safety precautions and follow L. B. White

recommendations when installing this heater. If

during the installation or relocating of heater, you

suspect that a part is damaged or defective, call a

qualified service agency for repair or replacement.

2. Insure that all accessories that ship within the heater

have been removed from inside of heater and

installed. This pertains to air diverters, hose,

regulators, etc.

3. A qualified service agency must check for proper

operating gas pressure upon installation of the heater.

4. L.B. White heaters can be configured for use with

either L.P. gas vapor withdrawal or natural gas.

Consult the dataplate, located on interior of the burner

end or motor end access door, for the gas

configuration of the specific heater. Do not use the

heater in an L.P. gas liquid withdrawal system or

application. If you are in doubt, contact the L.B. White

Co., Inc.

5. Eventually, like all electrical/mechanical devices, the

thermostat can fail. Thermostat failure may result in

either an underheating or overheating condition which

may damage critical products and/or cause animal

injury or death. Critical products and/or animals

should be protected by a separate back-up control

system that limits high and low temperatures and also

activates appropriate alarms.

6. Take time to explain to your customer how to operate

and maintain the heater by using this Service Guide.

Make sure your customer knows how to shut off the

gas supply to the building and also to the individual

heater. In the event of an emergency, have your

customer contact you or the fuel gas supplier if you

have any questions.

7. Any defects found in performing any of the service or

maintenance procedures must be eliminated and

defective parts replaced immediately. The heater

must be retested by properly qualified service

personnel before placing the heater back into use.

8. Do not exceed input rating stamped on the dataplate

of the heater. Do not exceed the burner manifold

pressure stated on the dataplate. Do not use an

orifice size different than specified for the specific

input rating of this heater, fuel type, configuration and

altitude.

August 1999

2.1-1

1

WARNING

Fire oor eexplosion hhazard.

Can ccause pproperty ddamage, ssevere iinjury oor ddeath.

Disconnect power supply before wiring to prevent

electrical shock or equipment damage.

To avoid dangerous accumulation of fuel gas, turn off

gas supply at the appliance service valve before

starting installation, and perform gas leak test after

completion of installation.

Do not force the gas control knob. Use only your hand

to turn the gas control knob. Never use any tools. If

the knob will not operate by hand, the control should

be replaced by a qualified service technician. Force or

attempted repair may result in fire or explosion.

Advertising