Servicing instructions – L.B. White Pilot User Manual

Page 59

Advertising
background image

Model AS040

Fan and Motor

Servicing

Instructions

Cleaning tthe FFan:

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to the heater.

2. Remove the motor access panel on the case back.

3. Disconnect the motor wires from the terminal strip.

4. Remove the screws that hold the motor mount to the

heat chamber. Pull the fan and motor assembly from

the heater.

5. Clean the fan with a soft brush, rag, or compressed air.

Motor aand FFan R

Replacement:

Follow steps 1 - 4 above and then proceed as follows:

1. Using the appropriate allen wrench, loosen the set

screw on the fan hub.

2. Remove the nuts that hold the motor to its mounting

bracket.

3. To reassemble, reverse the procedures.

IMPORTANT

Install the fan so its hub and set screw are pointed

toward shaft end, away from motor.

Fan hub must be flush with end of motor shaft.

Position set screw of fan to flat of motor shaft

before tightening.

August 1999