Preventative maintenance – L.B. White Pilot User Manual

Page 34

Advertising
background image

Cleaning Instructions

Preventative

Maintenance

4.2-1

1

1. Before cleaning, shut off all gas supply valves and

disconnect electrical supply.

2. The heater should have dirt or dust removed

periodically:

a. After each flock or between building re-population,

give the heater a general cleaning using

compressed air or a soft brush on its interior and

exterior. At this time, dust off the motor case to

prevent the motor from over-heating and shutting

the heater down.

b. At least once a year, give the heater a thorough

cleaning. At this time, remove the fan and motor

assembly and brush or blow off the fan wheel,

giving attention to the individual fan blades.

Additionally, make sure the burner air inlet venturi

ports and the throat of the casting are free of dust

accumulation and the area between the heat

chamber top and inside case is also free of dust.

c. Observe and obey all instructional warnings

pertaining to cleaning procedures located on each

heater.

August 1999

WARNING

Fire, B

Burn, aand EExplosion H

Hazard

This heater contains electrical and mechanical components in the gas management, safety and airflow systems.

Such components may become inoperative or fail due to dust, dirt, wear, aging, or the corrosive atmosphere of an

animal confinement building.

Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property

damage.