Electrical connection and ladder diagram, Wiring diagrams – L.B. White Pilot User Manual

Page 54

Advertising
background image

Wiring Diagrams

Electrical Connection

and Ladder Diagram

Used oon:

Model

Design Sequence

All

All

August 1999

7.1-2

2

ELECTRICAL LADDER DIAGRAM

ELECTRICAL CONNECTION DIAGRAM

WARNING: THIS HEATER MAY START AT ANY TIME

HIGH LIMIT

SWITCH

SOLENOID

AIR PROVING SWITCH

MOTOR

GROUND

THERMOSTAT

NEUTRAL

GROUND

MOTOR

HIGH LIMIT

SWITCH

GAS

CONTROL

VALVE

WHITE

WHITE

WHITE

BLACK

BLACK

BLACK

BLACK

BLACK

GREEN

BLA

CK

BLA

CK

BLACK OR RED

BLACK

OR RED

AIR PROVING SWITCH

(NOT SUPPLIED ON SOME MODELS)

POWER

CORD

THERMOSTAT

(OPTIONAL)

JUMPER
(REMOVE TO ADD
THERMOSTAT)

NOTE: IF AIR PROVING SWITCH IS NOT SUPPLIED, POWER IS SENT

DIRECTLY TO HIGH LIMIT SWITCH. SEE "DASHED" LINE.

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE

REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A

TEMPERATURE RATING OF AT LEAST 302

O

F (150

O

C).

Advertising