Servicing instructions – L.B. White Pilot User Manual

Page 55

Advertising
background image

Component Identification and Function

Servicing

Instructions

All components must work together for proper heater

operation. However, as with anything electrical or

mechanical, problems may arise which will require you to

determine what malfunction has occurred. Before you start

troubleshooting, it’s a good idea to understand the

components in their appearance and purpose.

Main O

Operational C

Components

A. Air PProving

A stainless steel flapper (sail) located

Flapper

in the blower outlet that upon an

increase in air pressure generated by

the fan and motor, lifts and pivots

upward and engages the air proving

switch arm, thereby closing the switch

contacts, establishing that the motor is

up to full speed and sufficient airflow is

present.

B. Air PProving

Safety device that proves that proper

Switch

motor speed and airflow is being

achieved before the gas control valve is

opened.

C. Burner

A device designed for the burning of

gas or a gas/air mixture in the

combustion zone.

D. Burner O

Orifice

Metering device which is drilled to a

specific diameter to allow a volume of

gas to be fed through the burner at the

stated manifold pressure (see

dataplate) to achieve proper heat

output.

August 1999