Servicing instructions – L.B. White Pilot User Manual

Page 61

Advertising
background image

Models 346/348, 408/410, AB200, AB250

Fan and Motor

Servicing

Instructions

Cleaning tthe FFan:

1. Shut off the gas supply to the heater and disconnect

the heater from its electrical supply.

2. Open or remove the access panel on the end of heater

opposite burner.

3. Disconnect the motor leads.

4. Remove the screws that secure the motor mount plate

to the fan housing.

5. Lift and pull the motor and fan assembly from housing.

6. Clean the fan wheel using a soft brush, rag, or

compressed air, paying particular attention to

individual fan blades to remove dirt build up.

Motor aand FFan R

Replacement:

Follow steps 1 - 5 above and then proceed as follows:

1. Loosen the set screw(s) on the fan wheel.

2. Pull the fan wheel from the motor shaft. Use a wheel

puller, if necessary. All L.B. White fan wheels

incorporate a wheel puller groove on the fan hub to

assist in fan removal.

3. Remove the nuts that hold the mounting plate to the

motor.

4. To reinstall motor and wheel, reverse these

procedures.

IMPORTANT

Make sure that the fan does not rub on the inlet ring

of the fan housing.

Make sure set screw(s) of fan are on flats of motor

shaft when tightening.

Fan wheel to motor mount plate spacing must be at

proper clearance before tightening fan to shaft.

Refer to the following table and illustration.

Model

Clearance

346/348

1/4 in.

408/410

AB200, AB250

August 1999

8.2-3

3

Nuts

CLEARANCE

1/8 in.