Servicing instructions – L.B. White Pilot User Manual

Page 57

Advertising
background image

Component Identification and Function

Servicing

Instructions

I. High LLimit S

Switch

A manually resetable temperature

activated switch. Its purpose is as

a safety device wired into the

control system to sense when an

overheat condition occurs, either

at the heat chamber or blower

outlet. The switch “opens” the

electrical circuit to the gas control

thereby shutting off gas flow. The

switch has a button located in its

center that will need to be pushed

in to reset the contacts if the

contacts open due to an overheat

condition.

J. Manifold

Series of nipples or elbows that

convey the gas from the outlet of

the gas control valve to the burner

orifice.

K. Motor

An electrically powered device,

located in the air housing, in

conjunction with the fan wheel to

circulate air in the confinement

area.

L. Pilot B

Burner B

Bracket A small gas burner used to direct

flame for igniting gas at the main

burner and to heat the

thermocouple.

M. Pilot Orifice

Metering device used to supply gas

for the dual purpose of igniting the

main burner and heating the

thermocouple.

August 1999