The preceding instructions dealing with inlet and manifold

pressure checks and leak testing generally apply to all

control valves. However, due to model and age variations of

heaters, there are several differences between control

valves with which you must be familiar.

Part number 500-02309 has burner manifold pressure

taps located on either side of the control valve’s main

solenoid.

The inlet pressure tap is located near the pilot button

and pilot line connection.

This control valve does not incorporate an internal gas

shut off nor low pressure regulator. All pressure

adjustments must be made at the second-stage

regulator supplying gas to the heater. Additionally, the

gas supply will need to be shut off at the supply line to

isolate the heater.