Installation instructions – L.B. White Pilot User Manual

Page 23

Advertising
background image

Remote Thermostat

Installation

Instructions

2.9-2

2

Models 3

346/348, 3

377/379, 4

408/410 ((Cont.)

9. Reconnect the heater to its electrical supply and open

the fuel supply valves to the inlet of the heater.

10. Light the pilot. Turn the thermostat up above room

temperature so the motor starts and main burner

ignites. Check the heater for proper operation.

11. Install the junction box cover plate. Tighten the plate

screws securely.

12. Set the thermostat to desired temperature.

Model AAS040

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to the inlet of the heater.

2. Remove the motor access panel located on the back of

the case assembly.

3. Remove the electrical enclosure cover.

4. Remove the electrical knock-out hole located directly

above the bushing that the power cord is routed through.

Install a two-screw squeeze connector into this hole and

route the cord through the connector. Tighten the

connector screws after allowing sufficient lead length to

reach the terminal strip.

5. Route the thermostat cord leads through the bushing

near the enclosure’s base.

6. Loosen the screws on the terminal strip that hold the

jumper in place. Remove the jumper.
(continued oon ffollowing ppage)

August 1999

Jumper

Bushing

Knockout

Advertising