Servicing instructions – L.B. White Pilot User Manual

Page 66

Advertising
background image

August 1999

8.6-1

1

Thermocouple

Servicing

Instructions

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to the heater.

2. Remove the screw(s) that secure the pilot assembly to

the burner.

3. Pull down on the thermocouple to disengage its

retaining clip from the pilot bracket, or loosen the

attachment nut (if so equipped).

4. Remove the connector nut at the power unit on the gas

control valve.

5. To reassemble, reverse these procedures.

6. Reconnect the heater to its electrical supply and open

the fuel supply valves to the heater.

7. Light the pilot.

8. Start the heater and check for proper operation.

ATTENTION

The thermocouple is an important safety device

which works directly with the pilot safety control

valve. It should only be replaced with a

thermocouple that has proper tip length to

prevent pilot outages. See parts lists to order the

appropriate thermocouple.

When threading the thermocouple’s connector

nut back into the power unit on the pilot control

valve, thread the nut in finger tight and then snug

it in place with the appropriate wrench. DO NOT

USE UNNECESSARY FORCE WHEN TIGHTENING,

otherwise the power unit in the control valve may

be destroyed.

CAUTION

Allow the pilot assembly to cool before servicing.

Nut