Basic Unit Description and Application

Pilot ignition agricultural building heaters are direct-fired,

non-vented heaters used in the heating of animal

confinement buildings (examples: swine, chicken, and

turkey). These heaters utilize a system that ignites the gas

by a conventional pilot flame rather than by direct spark or a

hot surface igniter. L.B. White offers you the most

dependable pilot system in the industry. Tested and proven

over time, these heaters provide simple yet reliable

operation.

As a non-vented heater, adequate ventilation must be

provided to ensure fresh air for combustion and removal of

combustion by-products from the building.

This style of heater is offered in a wide range of input ratings,

some with variable heat control, to help manage heating

needs efficiently.

All heaters referred to in this guide are to be mounted inside

the building at appropriate locations to help provide proper

warm air flow in the room being heated.

Key Markings; Purpose and Location

Markings constitute safety related information such as the

dataplate, start-up/shut-down instructions, warnings, etc.

that are applied on the heater to allow the qualified service

person or end user to operate the heater in a safe manner.

A. Dataplate

Purpose:

Used for identification of model number, and

configuration number and also critical information

such as safe clearances to combustibles, burner

manifold pressure, maximum and minimum

allowable inlet pressures, etc.

Typical Location:

Interior or exterior of burner end access panel.

Part No.:

Varies with design sequence and model number.

Contact L.B. White Co.

B. Start Up and Shut Down Procedures

Purpose:

Provides the basic information to safely start up and

shut down the heater and also provides cautionary

information relative to various safety aspects of

installation and application.

Typical Location:

Next to dataplate.

Part No.:

150-20158

Familiarize yourself with the location and content of all

markings. Location may vary depending on model. If any

markings are damaged or unreadable, replace the markings

immediately. Contact the L.B. White Company.

General

Information

August 1999

MODEL AW060

CONFIGURATION NO. AHPD210000
SERIAL NO.:

L. B. WHITE CO., INC. W6636 L.B. WHITE ROAD ONALASKA, WI 54650 608/783-5691

A

G S

DESI GN

CERTIFI ED

A

A

A

MERI C N

SSOCIATI O

N

MAXIMUM INPUT: 60,000 BTUH
TYPE FUEL: PROPANE VAPOR WITHDRAWAL
BURNER MANIFOLD PRESSURE 10.0 IN W.C. AT MAXIMUM INPUT
ELECTRICAL: 115 VOLTS A.C. 60 HZ SINGLE PHASE 1.5 AMPS
MIN. CLEARANCES FROM HEATER TO ADJACENT COMBUSTIBLE MATERIALS: REAR 1 FT SIDES 1 FT
TOP TO CEILING 1 FT BLOWER OUTLET 6 FT AND FUEL CONTAINER 6 FT
VENTILATION: 240 CFM OF AIR REQUIRED TO SUPPORT COMBUSTION.
MAXIMUM 13.5 INCHES W.C. AND MINIMUM 11.5 INCHES W.C. GAS SUPPLY PRESSURE
ACCEPTABLE AT INLET 0F HEATER FOR PURPOSE OF INPUT ADJUSTMENT.
POSITION HEATER AWAY FROM LIVESTOCK
AGRICULTURAL BUILDING HEATER

1.1-1

1

AB250

250,000