Installation instructions – L.B. White Pilot User Manual

Page 24

Advertising
background image

August 1999

2.9-3

3

Model AAS040 ((Cont.)

7. Attach the ground lead terminal to the ground screw in

the enclosure.

8. Push the exposed conductors of the power supply and

return leads beneath the terminal strip screw plates

previously occupied by the jumper. Tighten the screw

plates and tug on the leads to make sure the leads are

securely attached.

9. Reconnect the heater to its electrical supply and open

the fuel supply valves to the heater.

10. Check the heater for proper operation. Light the pilot

and set the thermostat so the fan motor starts and the

main burner ignites.

11. Disconnect the heater from its electrical supply.

Reinstall the electrical enclosure cover and the fan

access panel. Reconnect the heater to its electrical

supply. Set the thermostat to desired temperature.

Model AAB200 aand AAB250

1. Disconnect the heater from its electrical supply and

close all fuel gas valves to the inlet of the heater.

2. Open the burner access door to locate the heater’s

electrical enclosure. Remove the cover from the

enclosure.

3. Remove the hole plug from the thermostat cord entry

hole near the power cord at the front of the case

assembly.

4. Run the thermostat cord through this hole and through

the bushing in the base of the enclosure.

Remote Thermostat

Installation

Instructions

Ground

Lead

Advertising