Servicing instructions – L.B. White Pilot User Manual

Page 63

Advertising
background image

For U

Units W

With FFlapper:

1. Shut off gas supply and disconnect heater from

electrical source.

2. Disconnect air-proving switch leads.

3. Some models may have the air-proving switch

mounting nuts located on the inside of the fan

housing. Remove the motor and fan assembly from

the housing. Remove the nuts and pull the switch and

screws from the housing.

4. The replacement switch will ship with appropriate

quantity of nuts and two screws. Mount the

replacement switch so each mounting screw head is

located inside the fan housing with threads exposed

to the switch side of the housing.

Make sure on reassembly that two nuts per screw are

used as spacers between the switch and housing side

panel. These nuts are tightened securely against the

housing side panel. Slide the switch onto the screws

and secure the switch in place using the two

remaining nuts.

NOTE:

When replacing the switch, make sure the arm of the switch

is located above the flapper arm.

ATTENTION

Model 346 heaters do not include air proving

devices.

Model AS040 heaters incorporate a centrifugal

switch within the motor to prove that the motor as

turning at proper speed before supplying power to

the gas control valve. The centrifugal switch cannot

be replaced. If it fails, replace the motor.

Air-Proving Switch

Servicing

Instructions

August 1999

Screw H

Heads

Flapper

Two S

Spacer N

Nuts

per S

Screw

Flapper

Arm

8.4-1