Installation instructions – L.B. White Pilot User Manual

Page 22

Advertising
background image

Models 3

346/348, 3

377/379, 4

408/410

1. Disconnect the heater from its electrical supply and

close all fuel supply valves to the inlet of the heater.

2. Locate the two wires labeled “power supply to

thermostat” and “power return from the thermostat”

within the heater’s electrical junction box.

3. Remove the wire nuts from these two wires. Keep the

wire nuts.

4. Remove the strain relief at the top of the junction box.

5. Run the thermostat cord through the strain relief along

with the other wires that feed into the junction box. You

will need a pliers to squeeze the strain relief and wire

bundle together to allow installation of the strain relief

back into the junction box.

6. Connect the black thermostat cord lead to the lead

labeled “power supply to thermostat”. Twist a wire nut

onto the exposed lead conductors until tight. Pull the

wire nut to make sure it is secure.

7. Connect the white lead of the thermostat cord to the

lead labeled “power return from thermostat”. Twist a

wire nut onto the exposed lead conductors until tight.

Pull the wire nut to make sure it is secure.

8. Attach the terminal on the end of ground wire to the

ground screw located within the junction box.

Remote Thermostat

Installation

Instructions

August 1999

2.9-1

1

Strain

Relief

Black LLead

White LLead

Ground

Screw